关闭
 
读者在线:用户名 密码
首页 期刊简介 投稿须知 期刊目录 专家风采 编委会 特邀顾问 联系我们 移动出版
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5



刊物信息

期刊名称:药物分析杂志
主管单位:中国科学技术协会
主办单位:中国药学会
承办:中国食品药品检定研究院
主编:金少鸿
地址:北京天坛西里2号
邮政编码:100050
电话:010-67012819,67058427
电子邮箱:ywfx@nifdc.org.cn
国际标准刊号:ISSN 0254-1793
国内统一刊号:CN 11-2224/R
邮发代号:2-237
 

访问统计
您是第  1 2 3 1 0 0 1 8 位浏览者
您当前的位置:首页 >> 正文

LC-MS/MS测定人血浆中辛伐他汀及其活性代谢物的含量

LC-MS/MS determination of simvastatin and its active metabolite in human plasma

分类号:
出版年·卷·期(页码):2012,32 (9):0-0
DOI: 10.16155/j.0254-1793.2017.01.01
-----摘要:-------------------------------------------------------------------------------------------

目的:建立人血浆中辛伐他汀及其活性代谢物辛伐他汀酸的LC-MS/MS测定方法。方法:血浆样本在酸性条件下经甲基叔丁基醚液液萃取后,以2.5 mmol·L-1醋酸铵(含0.1%甲酸)-乙腈(25:75)为流动相,采用Inertsil ODS-3(2.1 mm×150 mm,5 μm)色谱柱分离。使用电喷雾离子源以多反应监测(MRM)方式分别进行正负离子监测。辛伐他汀选用洛伐他汀作为内标,在正离子模式下检测;代谢物辛伐他汀酸选用洛伐他汀酸作为内标,在负离子模式下监测。结果:测定血浆中辛伐他汀及其代谢物辛伐他汀酸的线性范围均为0.1~20.0 μg·L-1;方法回收率分别为86.1%~100.5%,91.5%~104.4%;日内精密度分别为3.2%~4.7%和4.5%~6.9%,日间精密度分别为3.6%~9.8%和2.3%~10.5%。结论:该方法简便快速、灵敏度高、重复性好,可准确的定量人血浆辛伐他汀及代谢物辛伐他汀酸的浓度,适用于辛伐他汀药代动力学研究。

-----英文摘要:---------------------------------------------------------------------------------------

Objective:To establish an LC-MS/MS method for the determination of simvastatin and its active metabolite(simvastatin acid)in human plasma. Methods:The acidified sample was extracted by MTBE,then separated on an Inertsil ODS-3(2.1 mm×150 mm,5 μm)column with 2.5 mmol·L-1 ammonium acetate(containing 0.1% formic acid)-acetonitrile(25:75)as mobile phase.Electrospray ionization source(ESI)was applied and operated in multiple reactions monitoring(MRM)mode.Simvastatin was detected in positive ion mode with lovastatin as internal standard,and its active metabolite was determined in negative ion mode with lovastatin acid as internal standard. Results:The calibration curves of simvastatin and its active metabolite were linear in the range of 0.1-20.0 μg·L-1.The method recoveries were 86.1%-100.5%% and 91.5%-104.4%,respectively.The intra-day precisions were 3.2%-4.7% and 4.5%-6.9%,respectively;the inter-day precisions were 3.6%-9.8% and 2.3%-10.5%,respectively. Conclusions:The method is simple,rapid,sensitive and reproducibility for the determination of simvastatin and its metabolite in human plasma.It is suitable for the pharmacokinetic study of simvastatin.

-----参考文献:---------------------------------------------------------------------------------------

欢迎阅读《药物分析杂志》!您是该文第 1122位读者!

药物分析杂志 © 2009
地址:北京天坛西里2号 邮政编码:100050; 电子邮件:ywfx@nicpbp.org.cn