目的: 建立离子色谱抑制电导法测定注射剂中的抗氧剂含量的方法。 方法: 采用阴离子交换柱AG-11HC保护柱和 AS11-HC分析柱(250 mm×4 mm,5 μm)以氢氧化钾溶液作淋洗液,进行梯度洗脱,抑制器电流值设定为149 mA,流速为1.0 mL·min-1,电导检测器测定注射剂中亚硫酸钠的总量。 结果: 亚硫酸钠在0.5074~507.444 μg·mL-1浓度范围内线性关系良好,相关系数分别为0.9998(n=5);定量限分别为0.16 μg·mL-1 (S/N≥10),检测限分别为0.05 μg·mL-1 (S/N≥3)。 结论: 本方法选择性高,灵敏度好,测定结果较为准确,可用于注射剂中抗氧剂的测定研究。
-----英文摘要:---------------------------------------------------------------------------------------
Objective: A suppressed conductivity ion chromatography method was established for determination of antioxidant in injections. Method: The AG-11HC anion guard column and the AS11-HC anion analytical column(250 mm×4 mm,5 μm)was employed to separate and determinate the sodium sulfite with the eluent of KOH using the gradient mode.The flow was 1.0 mL·min-1,and the suppressed currentset was 149 mA with conductivity detector. Results: Good linear relationship was established between the peak response and the concentration of 0.5074-507.444 μg·mL-1with the quantitation limit (S/N=10) of 0.16 μg·mL-1,and the detection limit (S/N=3) of 0.05 μg·mL-1. Conclusion: The proposed method shows high selectivity,sensitivity and good results.It can be employed for the quality control and research of antioxidants in injections.
-----参考文献:---------------------------------------------------------------------------------------
[1] ChP(中国药典).2010.Vol Ⅱ(二部)附录:6
[2] ZHENG Ce(郑策),MEI Dan(梅丹),WANG Lan(王兰),et al.Adverse effect of excipients in pharmaceutical products(关注制剂中辅料的不良反应).Chin Pharm J(中国药学杂志),2005,40(9):644
[3] LU Ke-ping(陆克平).Simultaneous determination of Cl-and SO42- in 30% sodium bisulfite solution samples by ion chromatography(30%亚硫酸钠溶液样品中Cl-和 SO42- in 的同时测定).Chin J Chromatogr(色谱),2005,23(3):205
[4] Christian P,Sylviane J.Isotope dilution-chemical separation:a powerful combination for high precision analysis at the ultra-trace level using ICP mass spectrometry;example of U and Th determination in silicate rocks.J Anal At Spectrom,2001,16:73
欢迎阅读《药物分析杂志》!您是该文第 1578位读者!