目的:建立HPLC法对乳酸菌素制剂中L-乳酸和D-乳酸对映体进行拆分,并测定两者在乳酸菌素制剂中的含量与比例,运用L-乳酸和D-乳酸比值对搜集到的样本进行可能的工艺稳定性评价。方法:采用手性柱Chirex 3126(D青霉胺)-Phenomenex(250 mm×4.6 mm,5 μm)色谱柱,以2 mmol·L-1硫酸铜溶液-异丙醇(95:5)为流动相,流速1.0 mL·min-1,紫外检测波长254 nm,柱温为30 ℃。结果:L-乳酸与D-乳酸质量浓度在0.10~1.04 mg·mL-1范围内均呈良好线性(r=0.999 9);平均回收率(n=9)分别为97.5%和98.3%;检测限分别为0.094 4和0.124 6 μg·mL-1;供试品溶液在48 h内稳定性良好;总体样本L-乳酸和D-乳酸比值在0.93~1.68之间。结论:该方法简单快捷,适合于乳酸菌素制剂中乳酸对映体的含量测定研究,用L-乳酸和D-乳酸比值经统计可以观察样本间离散程度,能反映出各厂间工艺稳定性水平。
-----英文摘要:---------------------------------------------------------------------------------------
Objective:To establish an HPLC method for enantiomer separation of L-lactic acid and D-lactic acid,assay the L-lactic acid and D-lactic acid isomer and their ratios in some lacidophilus preparations and use L-lactic acid and D-lactic acid ratio of the collected samples for possible evaluation of process stability.Methods:The separation was performed on a Chirex 3126(D-penicillamine)chiral column(250 mm×4.6 mm,5 μm)and detected by ultraviolet detector(UV).The detection wavelength was set at 254 nm.The column temperature was set at 30 ℃.The mobile phase consisted of 2 mmol·L-1 copper sulfate solution - isopropyl alcohol(95:5)at a flow rate of 1.0 mL·min-1.Results:The calibration curve of L-lactic acid and D-lactic acid was linear in the range of 0.10-1.04 mg·mL-1(r=0.999 9);the average recoveries(n=9)of the method were 97.5% and 98.3%,respectively;the limits of detection were 0.094 4 μg·mL-1 and 0.124 6 μg·mL-1,respectively;the sample solution was stable within 48 h.The ratio range of L-lactic acid to D-lactic acid in total samples was 0.93-1.68.Conclusion:The method is simple,accurate and sensitive,and suitable for the determination of L-lactic acid and D-lactic acid in lacidophilus preparation,and the L-lactic acid and D-lactic acid ratio of the statistical sample can be used to observe the degree of dispersion and reflect process stability level of each pharmaceutical factory.
-----参考文献:---------------------------------------------------------------------------------------
欢迎阅读《药物分析杂志》!您是该文第 600位读者!
|