凝胶色谱-蒸发光散射检测法测定紫杉醇脂肪乳注射液中泊洛沙姆188的含量
Determination of poloxamer 188 in paclitaxel lipid emulsion injections by GPC-ELSD
分类号:
出版年·卷·期(页码):2014,34 (7):0-0
DOI:
10.16155/j.0254-1793.2017.01.01
-----摘要:-------------------------------------------------------------------------------------------
目的:建立凝胶色谱-蒸发光散射检测法(GPC-ELSD)测定紫杉醇脂肪乳注射液中泊洛沙姆188的含量。 方法:采用UltrahydrogelTM(7.8 mm×300 mm,250 Å)水性凝胶柱,以乙腈-水(20:80)为流动相,流速1.0 mL·min-1,蒸发光散射器的漂移管温度为50℃,载气流速为1.9 L·min-1,进样量20 μL。 结果:泊洛沙姆188浓度在0.4~1.2 mg·mL-1范围内线性关系良好(r=0.9998);定量限为0.8 μg;泊洛沙姆188的平均回收率(n=9)为101.6%,RSD为0.65%;脂肪乳中的其他成分对检测没有干扰。 结论:该检测方法经方法学验证,适用于紫杉醇脂肪乳注射液中泊洛沙姆188的含量测定。
-----英文摘要:---------------------------------------------------------------------------------------
Objective: To establish a method for determination of the concentration of poloxamer 188 in paclitaxel lipid emulsion injections by gel permeation chromatography-evaporative light scattering detector(GPC-ELSD). Methods: The separation was performed on an UltrahydrogelTM column(7.8 mm×300 mm,250 Å)with the mobile phase consisting of acetonitrile-water(20: 80).The flow rate was 1.0 mL·min-1 and the injection volume was 20 μL.The drift tube temperature of the ELSD was set at 50℃,and the gas flow rate was 1.9 L·min-1. Results: Under the above described condition,the linear concentration range of poloxamer 188 was 0.4-1.2 mg·mL-1(r=0.9998).The detection limit was 0.8 μg for Poloxamer 188.The average recovery rate(n=9) was 101.6%,and the RSD was 0.65%.There was no influence of other ingredients on the determination. Conclusion: The methodology validation shows that the established method is suitable for the determination of poloxamer 188 in paclitaxel lipid emulsion injections.
-----参考文献:---------------------------------------------------------------------------------------
[1] ZHOU Qiao-yun(周巧云),ZHANG Zhao-hui(张朝晖),PAN Jun-fang(潘俊芳),et al.Development of poloxamers used as carriers for new dosage forms of hydrophobic drugs(泊洛沙姆为载体的疏水性药物新剂型研究进展)[J].Chin J Mod Appl Pharm(中国现代应用药学),2011,28(4):315
[2] WANG Meng(王猛),ZHANG Jun-shou(张钧寿),ZHOU Jian-ping(周建平).An injectable excipient:Poloxamer 188(注射用辅料泊洛沙姆188)[J].Pharm Clin Res(药学与临床研究),2007,15(1):10
[3] Xia XJ,Guo RF,Liu YL,et al.Formulation,characterization and hypersensitivity evaluation of anintravenous emulsion loaded with a paclitaxel-cholesterol complex[J].Chem Pharm Bull (Tokyo),2011,59(3):321
[4] Gelderblom H,Verweij J,Nooter K,et al.Cremophor EL:the drawbacks and advamages of vehicle selection for drug formulation[J].Eur J Cancer,2001,37(13):1590
[5] LI Jia-zhong(李家忠),ZHANG Li(张莉),HE Tao(何涛),et al.Spectrophotometric study of poloxamer in contact lens care solution(分光光度法测定角膜接触镜护理液中泊洛沙姆含量) [J].J Shanghai Jiaotong Univ(Med Sci)(上海交通大学学报医学版),2010,30(2):244
[6] ChP 2010.Vol Ⅱ(中国药典2010年版.二部)[S].2010:1208
[7] Lakshmy MN,Jamie K,Mary T,et al.Comparison of electrospray ionization mass spectrometry and evaporative light scattering detections for the determination of Poloxamer 188 in itraconazole injectable formulation[J].J Pharm Biomed Anal,2006,41(3):725
[8] Erlandsson B,Wittgren B,Brinkmalm G.Development of a size exclusion chromatography method for the determination of molar mass for poloxamers[J].J Pharm Biomed Anal,2003,31(5):845
[9] Mao Y,Thompson MJ,Wang QX,et al.Quantitation of poloxamers in pharmaceutical formulations using size exclusion chromatography and colorimetric methods[J].J Pharm Biomed Anal,2004,35(5):1127
[10] Gallet G,Carroccio S,Rizzarelli P,et al.Thermal degradation of poly(ethylene oxide-propylene oxide-ethylene oxide) triblock copolymer:comparative study by SEC/NMR,SEC/MALDI-TOF-MS and SPME/GC-MS[J].Polymer,2002,43(4):1081
[11] Miszkiewicz W,Szymanowski J.Analysis of nonionic surfactants with polyoxyethylene chains by high-performance liquid chromatography[J].Crit Rev Anal Chem,1996,25:143
[12] WANG Qiao-e(王巧娥),DING Ming-yu(丁明玉).Progress on evaporative light-scattering detection(蒸发光散射检测技术研究进展)[J].J Instrum Anal(分析测试学报),2006,11,25(6):126
欢迎阅读《药物分析杂志》!您是该文第 1058位读者!