-----摘要:-------------------------------------------------------------------------------------------
摘要 目的:建立RP-HPLC法测定氟哌利多注射液的有关物质及含量的检测方法。方法:采用Diamonsil C18(150 mm×4.6 mm,5 μm) 色谱柱,流动相为水-乙腈-三乙胺(70:30:0.9),醋酸调pH至5.9,流速:1.0 mL•min-1,检测波长:275nm,柱温:35℃。结果:氟哌利多的线性范围为50~150 μg•mL-1,相关系数为:0.9996。回收率(n=9)为100.8%。结论:该方法简便准确,重复性好,可为控制氟哌利多注射液的含量和有关物质的质量标准提供参考。
-----英文摘要:---------------------------------------------------------------------------------------
Abstract Objective: To establish an RP-HPLC method to determine the contents of droperidol injection and its related substances. Methods: The contents of injectio droperidoli was measured by RP-HPLC with a column of Diamonsil C18(150 mm×4.6 mm,5 μm), water-acetonitrile-triethylamine(70:30:0.9),adjust the pH to 5.9 with acetic acid as mobile phase,the flow rate was 1.0 mL•min-1, the detection wavelengths was 275 nm, the column temperature was 35 ℃.Results: The calibration curves showed good linearity in the range of 50-150 μg•mL-1,correlation coefficients was 0.9996. The average recoveries (n=9) was 100.8%.Conclusion: An accurate and reproducible method can be used for the quality control of injectio droperidoli.
-----参考文献:---------------------------------------------------------------------------------------
1. Drug Specification Promulgated by the ministry of Public Health,PR China.Part2,Vol.4, (卫生部药品标准二部第四册):1996:70,71