目的:建立米铂脂质体中米铂的含量测定方法。方法:采用HPLC法测定米铂脂质体中米铂的含量。色谱条件:采用Agilent C8色谱柱(250 mm×4.6 mm,5 μm),以甲醇-水(92∶8)为流动相,流速1.0 mL·min-1,检测波长210 nm,柱温30℃,进样量20 μL。结果:色谱分离度R=2.91,阴性对照无干扰;米铂在3.37~115.11 μg·mL-1范围内线性关系良好(r=0.999 9);低、中、高3种浓度的平均回收率分别为97.1%(RSD=0.90%,n=3)、97.0%(RSD=0.10%,n=3)和98.7%(RSD=0.59%,n=3);日内精密度RSD=0.75%(n=6),日间精密RSD=1.0%(n=6);流速在0.99~1.01 mL·min-1范围内变化时RSD=0.49%(n=9),柱温在28~32℃之间变化时RSD=1.7%(n=9)。结论:本文建立的方法简便易行,稳定,准确,专属性强,耐用性好;可定量检测米铂脂质体中米铂的含量。

-----英文摘要:---------------------------------------------------------------------------------------

Objectives: To establish an HPLC method for the quantification of miriplatin in miriplatin-loaded liposomes (lipomiriplatin).Methods: The detection was performed on an Agilent C8 column (250 mm×4.6 mm, 5 μm) at 210 nm.An isocratic elution was used with methanol and water (92:8) as the mobile phase at a flow rate of 1.0 mL·min-1.Results: The method was validated:with a resolution of 2.91;linear, in the range of 3.37-115.11 μg·mL-1(r=0.999 9) and accurate, with the average recovery rate of 97.1% (RSD=0.90%, n=3)、97.0% (RSD=0.10%, n=3) and 98.7% (RSD=0.59%, n=3) at low, medium and high concentrations;precision, inter-day and intra-day precision reflected by the relative standard deviation(RSD) values of 0.75% (n=6) and 1.0% (n=6) respectively, robust under slight change of flow rate (0.99-1.01 mL·min-1) and column temperature (28-32℃) with RSD of 0.49% (n=9) and 1.7% (n=9), respectively.Conclusion: A simple, selective, sensitive and robust HPLC method has been established for the determination of miriplatin loaded in lipomiriplatin.